55

Note on the input/output of parameter and

compensation-value lists

With a terminal program (e.g. Hyper Terminal, included with

Windows

®

), you can receive the lists output by the display unit over

the RS-232-C/V.24 interface as text files and store them on your

PC. Each list must be saved as a separate text file. To transfer the

text files to the display unit, you can also use the terminal program.
If you wish, you can edit the text files with a text editor and

change, for example, the parameter values. However, this requires

knowledge of the different output structures of the lists (see the

following pages). When receiving lists, the display unit assumes the

same list structure as used for the output.

When receiving lists, the display unit first waits for the starting

character < * >.

The receiving mode ends as soon as the display unit has received

the final character < * >.
The lists received are first checked for the type of display unit

(line 2 of output list). The receiving display unit accepts only lists

prepared by the same type of display unit. Furthermore, the list is

checked for completeness. Lists that contain, for example, too

many or too few parameters are ignored. If an error occurs, the

following error message appears:
REC. ERROR
To clear the error message, press the CL key.
When receiving non-valid parameter values, the display unit sets

the respective operating parameter to the default setting.

Example: "P01 INCH = INCH = 3"

Value 3 is not allowed. The parameter P01 is set to the default
setting "P01 MM = MM = 0".

Input/Output

of

Parameter

and

Compensation-Value

Lists

The display unit is ready to receive a

compensation value list (X, Y or Z) over

the RS-232-C/V.24 interface. If no error

occurs during the reception of the

parameter list, the display unit returns to

"TRANSFER" to send or receive further

lists. To proceed with the data transfer

menu, press the minus key.

REC. COMP.

If req.

Exit the transfer function.

or

SPEC

FCT

With the ENT key, the compensation

value list for the Y axis is output over the

RS-232-C/V.24 interface. After output is

completed, the display unit returns to

"TRANSFER" to send or receive further

lists. To proceed with the data transfer

menu, press the minus key.

SEND COMP.Y

ENT

If req.

With the ENT key, the compensation

value list for the Z axis is output over the

RS-232-C/V.24 interface. After output is

completed, the display unit returns to

"TRANSFER" to send or receive further

lists. To proceed with the data transfer

menu, press the minus key.

SEND COMP.Z

ENT

If req.

1)

1) Only with ND 760