37

Operating

Parameters

List of operating parameters

P00 CODE Enter code number
9 51 48:

Change protected operating parameters

66 55 44:

Display the software version (in the X axis)

Display the date of release (in the Y axis)

10 52 96:

Multipoint axis error compensation

48 61 53:

Input and output of parameter lists and

compensation-value lists

P01 Unit of measure

1)

Display in millimeters

MM

Display in inches

INCH

P03.1 to P03.3 Radius/diameter display

1)

Display position value as radius

RADIUS

Display position value as diameter

DIAMETER

P11 Activate scaling factor

1)

Active

SCALING ON

Not active

SCALING OFF

P12.1 to P12.3 Define scaling factor

1)

Enter a scaling factor separately for each axis:

Entry value > 1: workpiece will “grow”

Entry value = 1: workpiece will remain the same size

Entry value < 1: workpiece will “shrink”

Input range:

0.100000 to 9.999999

Default setting:

1.000000

P25 Stylus diameter

1)

Input range (mm):

0.000 to 999.999

Default setting:

6

P26 Stylus length

1)

Input range (mm):

0.000 to 999.999

P30.1 to P30.3 Counting direction
Positive counting direction with

positive direction of traverse

DIRECT. POS

Negative counting direction with

positive direction of traverse

DIRECT. NEG

P31.1 to P31.3 Signal period of the encoder
Input range:

0.00000001 to 99999.9999 µm

Default setting:

20 µm

P33.1 to P33.3 Counting mode
0 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9

0 - 2 - 4 - 6 - 8

0 - 5

P38.1 to P38.3 Decimal places

2 / 3 / 4 / 5 / 6 / 7 / 8

1)

User parameter