47

15

GND

9
3
4
5

10

11

7

TXD
RXD
RTS
CTS
DSR
GND

SIGNAL

DTR

CHASSIS

GND
TXD
RXD
RTS
CTS
DSR
GND

SIGNAL

DTR

CHASSIS

Simplified wiring

Full wiring

RS-232-C/V.24

In addition to a connection for the edge finder, the X10 socket also

provides an RS-232-C/V.24 data interface.

The data interface on your ND display unit enables you to use a printer or

a PC for transferring measured values or programs.

The interface is permanently set to the following data format:

1 start bit

7 data bits

Even parity bit

2 stop bits

The baud rate is set with parameter P50.

For connection to peripheral devices you can use either full wiring

(figure at upper right) or simplified wiring (below right).

RS-232-C

/

V

.24

Data

Interface

15

GND

9
3
4
5

10

11

7

TXD
RXD
RTS
CTS
DSR
GND

SIGNAL

DTR

CHASSIS

GND
TXD
RXD
RTS
CTS
DSR
GND

SIGNAL

DTR

CHASSIS

Levels for TXD and RXD

Logic levels

Voltage levels

“1”

– 3 V to – 15 V

“0”

+ 3 V to +15 V

Levels for RTS, CTS, DSR and DTR

Logic levels

Voltage levels

“1”

+ 3 V to +15 V

“0”

– 3 V to – 15 V