61
Output
Structure
of
Parameter
Lists
Parameter list
Description
P41.3
LINEAR CMP. =
+ 0
Z axis: LINEAR COMPENSATION = 0 µm/m (value input)
P42.1
BKLASH =
+ 0.000
X axis: BACKLASH compensation 0.000 mm (value input)
P42.2
BKLASH =
+ 0.000
Y axis: BACKLASH compensation 0.000 mm (value input)
P42.3
BKLASH =
+ 0.000
Z axis: BACKLASH compensation 0.000 mm (value input)
P43.1
1000 SP =
1000
X axis: ONE REF.MARK = 0; 500; 1000; 2000; 5000 SP;
P43.2
1000 SP =
1000
Y axis: ONE REF.MARK = 0; 500; 1000; 2000; 5000 SP;
P43.3
1000 SP =
1000
Z axis: ONE REF.MARK = 0; 500; 1000; 2000; 5000 SP;
P44.1
REF. ON =
1
X axis: REF.ON = 1; REF. OFF = 0;
P44.2
REF. ON =
1
Y axis: REF.ON = 1; REF. OFF = 0;
P44.3
REF. ON =
1
Z axis: REF.ON = 1; REF. OFF = 0;
P45.1
ALARM ON =
1
X axis: ALARM ON = 1; ALARM OFF = 0;
P45.2
ALARM ON =
1
Y axis: ALARM ON = 1; ALARM OFF = 0;
P45.3
ALARM ON =
1
Z axis: ALARM ON = 1; ALARM OFF = 0;
P48.1
AXIS ON =
1
X axis: AXIS ON = 1; AXIS OFF = 0;
P48.2
AXIS ON =
1
Y axis: AXIS ON = 1; AXIS OFF = 0;
P48.3
AXIS ON =
1
Z axis: AXIS ON = 1; AXIS OFF = 0;
P49.1
AXIS NAME =
88
X axis: AXIS NAME = 88; (0 - 127)
P49.2
AXIS NAME =
89
Y axis: AXIS NAME = 89; (0 - 127)
P49.3
AXIS NAME =
90
Z axis: AXIS NAME = 90; (0 - 127)
P50
9600 BAUD =
9600
BAUD RATE = 9600; (110-38400)
P51
EMPTY LINES =
1
LINE FEEDS = 1; (0 - 99)
P70
2 DATUM PT. =
2
2 DATUM POINTS = 2; 9 DATUM POINTS = 9;
P80
CL......OFF =
0
CL....OFF = 0; CL....RESET = 1;
P81
1/2 OFF =
0
½ KEY OFF = 0; ½ KEY ON = 1;
P96
PROBING OFF =
0
PROBING OFF = 0; PROBING ON = 1;
P97
OUTPUT ID. =
0
OUTPUT ID. = 0; (0 - 127)
P98
LANGUAGE DE =
1
LANGUAGE: 0 = EN;
1 = DE;
2 = FR;
*
3 = IT;
4 = NL;
5 = ES;
6 = DA;
7 = SV;
8 = FI;
9 = CS;
10 = PL; 11= HU; 12 = PT;
Final character (*);
Bateil2.pm6
27.03.2002, 12:09
61