HEIDENHAIN ND 720 v.3 User Manual
Page 39

39
Operating
Parameters
P50 Baud rate
1)
110 / 150 / 300 / 600 / 1200 / 2 400 / 4 800 / 9600 /
19 200 / 38 400
P51 Line feeds for measured value output
1)
Input range:
0 to 99
Default setting:
1
P70 Number of datum points
2 datum points
2 DATUM PT.
9 datum points
9 DATUM PT.
P80 Function of the CL key
Set to zero with CL
CL....RESET
No set to zero with CL
CL......OFF
P81 Function of the R+/- key
The R+/- key divides the actual
R+/- 1/2 ON
value by two.
The actual value is not divided.
R+/- 1/2 OFF
P96 Measured value output for probing
Measured value output active
PROBE ON
Measured value output not active
PROBE OFF
1)
User parameter
P97 Characters for measured values
ASCII characters for designation of the measured values for
output through probing, contact, or pulse.
Input range:
0 to 127
No ASCII character
0
ASCII character from ASCII table
1 to 127
P98 Conversational language
1)
German
LANGUAGE DE
English
LANGUAGE EN
French
LANGUAGE FR
Italian
LANGUAGE IT
Dutch
LANGUAGE NL
Spanish
LANGUAGE ES
Danish
LANGUAGE DA
Swedish
LANGUAGE SV
Finnish
LANGUAGE FI
Czech
LANGUAGE CS
Polish
LANGUAGE PL
Hungarian
LANGUAGE HU
Portuguese
LANGUAGE PT
Bateil2.pm6
27.03.2002, 12:09
39