9 adaptation of the data interfaces 4–66, 9 adaptation of the data interfaces – HEIDENHAIN TNC 370D User Manual
Page 69
![background image](https://www.manualsdir.com/files/815334/content/doc069.png)
4–66
TNC 370 D
Machine Parameters
July 02
4.9 Adaptation of the Data Interfaces
Machine
parameter
Function and input
Change via
Reaction
MP5020.0-2
Data format EXT1 to EXT3
Input: %xxxxxxxxx
Bit 0
0 = 7 data bits
1 = 8 data bits
Bit 1
0 = BCC any
1 = BCC not control character
Bit 2
Transmission stop through RTS
0 = not active
1 = active
Bit 3
Transmission stop through DC3
0 = not active
1 = active
Bit 4
0 = even parity
1 = odd parity
Bit 5
0 = parity not required
1 = parity required
Bit 6/7 Stop bits Bit 6
Bit 7
1½ stop bits 0
0
2 stop bits
1
0
1 stop bit
0/1
1/1
Bit 8 0= RTS always active
1= RTS only active when data
transfer is started
Bit 9 0= EOT sent after EXT
1= EOT not sent after EXT
CN
PLC
RUN
MP5030.0-2
MP5030.0 Operating mode EXT1
MP5030.1 Operating mode EXT2
MP5030.2 Operating mode EXT3 (PLC)
Input:
0 = "standard data transfer"
1 = "blockwise transfer"
CN
PLC
RUN
MP5040
Data transfer rate in operating mode EXT3
(data transfer via PLC)
Input:
0 = 110 baud
6 = 4800 baud
1 = 150 baud
7 = 9600 baud
2 = 300 baud
8 = 19 200 baud
3 = 600 baud
9 = 38 400 baud
4 = 1200 baud
10 = 57 600 baud
5 = 2400 baud
11 = 115 200 baud
PLC
RUN