beautypg.com

9 adaptation of the data interfaces 4–66, 9 adaptation of the data interfaces – HEIDENHAIN TNC 370D User Manual

Page 69

background image

4–66

TNC 370 D

Machine Parameters

July 02

4.9 Adaptation of the Data Interfaces

Machine
parameter

Function and input

Change via

Reaction

MP5020.0-2

Data format EXT1 to EXT3
Input: %xxxxxxxxx
Bit 0

0 = 7 data bits

1 = 8 data bits

Bit 1

0 = BCC any

1 = BCC not control character

Bit 2

Transmission stop through RTS

0 = not active

1 = active

Bit 3

Transmission stop through DC3

0 = not active

1 = active

Bit 4

0 = even parity

1 = odd parity

Bit 5

0 = parity not required

1 = parity required

Bit 6/7 Stop bits Bit 6

Bit 7

1½ stop bits 0

0

2 stop bits

1

0

1 stop bit

0/1

1/1

Bit 8 0= RTS always active
1= RTS only active when data
transfer is started
Bit 9 0= EOT sent after EXT
1= EOT not sent after EXT

CN
PLC
RUN

MP5030.0-2

MP5030.0 Operating mode EXT1
MP5030.1 Operating mode EXT2
MP5030.2 Operating mode EXT3 (PLC)
Input:
0 = "standard data transfer"
1 = "blockwise transfer"

CN
PLC
RUN

MP5040

Data transfer rate in operating mode EXT3
(data transfer via PLC)
Input:
0 = 110 baud

6 = 4800 baud

1 = 150 baud

7 = 9600 baud

2 = 300 baud

8 = 19 200 baud

3 = 600 baud

9 = 38 400 baud

4 = 1200 baud

10 = 57 600 baud

5 = 2400 baud

11 = 115 200 baud

PLC
RUN