beautypg.com

4 reference signal for the spindle, 5 supply voltage for "control-is-ready, 5 supply voltage for control-is-ready signal – HEIDENHAIN TNC 370D User Manual

Page 17

background image

3–14

TNC 370 D

Mounting and Electrical Installation

July 02

3.7.4 Reference Signal for the Spindle


Usually, the reference mark of the spindle encoder is evaluated as a reference signal for the spindle.
In special cases, a 24 V signal on terminal X30 can be evaluated as a reference signal for the spindle
or as a reference signal release (see chapter “Spindle”). For reliable evaluation, the signal must last
for at least 3 milliseconds.

X30 Spindle Reference Signal

Terminal Assignment

1

+24 V input

2

0 V





3.7.5 Supply voltage for Control-is-Ready Signal


The power supply for the control-is-ready signal is taken from the 24 V power supply of the PLC.

X34 power supply for control-is-ready signal

Connecting terminal

Assignment

1

+24 V PLC

2 0

V