beautypg.com

HEIDENHAIN TNC 370D User Manual

Page 54

background image

July 02

Machine Parameters

TNC 370 D

4–51

Select Machine Parameter File (Module 9033)
With Module 9033 you select an editable machine parameter file. The module does not cause a
system reset, but it does reinitialize the NC. The file name is specified in an empty string, since at
the time a new editable machine parameter file is being handled. Once the NC program has started
the module operates only during the output of M/S/T/Q strobes.

Call only from a Submit job:
PS B/W/D/K

0 to 3

CM 9033

Note: Program execution ends here if a new file is selected.

PL

B/W/D

0:

No error, file was already selected

1:

The specified string does not conform to the above conventions.

2:

File found not

3:

File is faulty

4:

Incorrect string was transferred (out of range 0 to 3)

5:

The module was not called from a Submit job.

6:

The module was called after the NC program started without a strobe
marker being active.



Loading a Machine Parameter Partial File (Module 9034)
With Module 9034 you load the contents of the given machine parameter file into the main
memory. All parameters not contained in this file remained unchanged. The new MP file to be
selected is checked; no faulty files are loaded. The MP file is not loaded if it contains parameters
that require a system reset. The file name is transferred in a string that must contain the complete
file name. Additional characters (including blank characters) are not allowed. If a RESET MP is
overwritten, an error code is sent. If the PLC program is created externally, ensure that lower-case
letters are not used for the file name. Once the NC program has started the module only operates
during the output of M/S/T/Q strobes.

Call only from a Submit job:
PS B/W/D/K

0 to 3

CM 9034
PL

B/W/D

0: No

error

1:

String does not have a valid file name, or the name (including path) is too
long

2:

File found not

3:

File is faulty / File contains reset parameters

4:

Incorrect string number was transferred (out of range 0 to 3)

5:

The module was not called from a Submit job.

6:

The module was called after the NC program started without a strobe
marker being active.