beautypg.com

HEIDENHAIN TNC 370D User Manual

Page 68

background image

July 02

Machine Parameters

TNC 370 D

4–65

Machine
parameter

Function and input

Change via

Reaction

MP4131



MP4131.0

MP4131.1
MP4131.2

MP4131.3

MP4131.4

MP4131.5

Criterion for activating the fast PLC input
from MP4130
Input:

0 = Activation at Low level

1 = Activation at High level

Fast PLC input for switching off the
monitoring functions
No function
Fast PLC input for sets M4590
(signal duration > 6 ms)
Fast PLC input sets M4591
(signal duration > 6 ms)
Fast PLC input sets M4592
(signal duration > 6 ms)
Fast PLC input sets M4593
(signal duration > 6 ms)

MP4210.0-47 Setting a number in the PLC (D768 to

D956)
Input: –30 000.000 to +30 000.000 [mm]

MP4220.0-3

Setting a number in the PLC (Word range
W960 to W968)
Input: 0 to 65 535

MP4230.0-31 Setting a number in the PLC (Module

9032)
Input: –99 999.999 to +99 999.999

MP4231.0-31 Setting a number in the PLC (Module

9032)
Input: –99 999.999 to +99 999.999

MP4310.0-6

Setting a number in the PLC
(W976 to W988)
Input: 0 to 65 535

$0000 to $FFFF