HEIDENHAIN TNC 370D User Manual
Page 57
4–54
TNC 370 D
Machine Parameters
July 02
Machine
parameter
Function and input
Change via
Reaction
MP115.0
Position encoder inputs 1V
PP
or 11µA
Input: %xxxxx
0 = 1V
PP
1 = 11µA
Reset
MP115.1 Reserved
Input: %00000
MP115.2
Input frequency of position encoders
Input: %xxxxx
0 = 50kHz for 1V
PP
; 50kHz for 11µA
1 = 350kHz for 1V
PP
; 150kHz for 11µA
Reset
MP120.0-3 Assignment
of
the nominal value output
for the axes
Input:
0 = no controlled axis
1 = analog nominal value to X8/1
2 = analog nominal value to X8/2
3 = analog nominal value to X8/3
4 = analog nominal value to X8/4
5 = analog nominal value to X8/5
Reset
MP121
Assignment of the nominal value output
for the spindle
Input:
0 = no controlled spindle
1 = analog nominal value to X8/1
2 = analog nominal value to X8/2
3 = analog nominal value to X8/3
4 = analog nominal value to X8/4
5 = analog nominal value to X8/5
Reset
MP210
Count direction of the measuring system
signals of the position measuring system
Input: %00xxxx
Bit
0 to 3
0 = not active
Axis
X to 4
1 = active
Bits 4 and 5 reserved, enter 0
MP331.0-3
Distance per number of signal periods out of
MP332
Input: 0.001 to 99 999.999
[mm or °]
MP332.0-3
Number of signal periods in the distance
from MP331
Input: 1 to 16 777 215
MP334.0-3
Distance between reference marks for
encoders with distance-coded reference
marks
Input:
0 to 65535 [grating periods]
0=1000 grating periods
(standard setting)