4–54

TNC 370 D

Machine Parameters

July 02

Machine
parameter

Function and input

Change via

Reaction

MP115.0

Position encoder inputs 1V

PP

or 11µA

Input: %xxxxx
0 = 1V

PP

1 = 11µA

Reset

MP115.1 Reserved

Input: %00000

MP115.2

Input frequency of position encoders
Input: %xxxxx
0 = 50kHz for 1V

PP

; 50kHz for 11µA

1 = 350kHz for 1V

PP

; 150kHz for 11µA

Reset

MP120.0-3 Assignment

of

the nominal value output

for the axes
Input:

0 = no controlled axis

1 = analog nominal value to X8/1
2 = analog nominal value to X8/2
3 = analog nominal value to X8/3
4 = analog nominal value to X8/4
5 = analog nominal value to X8/5

Reset

MP121

Assignment of the nominal value output
for the spindle
Input:

0 = no controlled spindle

1 = analog nominal value to X8/1
2 = analog nominal value to X8/2
3 = analog nominal value to X8/3
4 = analog nominal value to X8/4
5 = analog nominal value to X8/5

Reset

MP210

Count direction of the measuring system
signals of the position measuring system
Input: %00xxxx
Bit

0 to 3

0 = not active

Axis

X to 4

1 = active

Bits 4 and 5 reserved, enter 0

MP331.0-3

Distance per number of signal periods out of
MP332
Input: 0.001 to 99 999.999

[mm or °]

MP332.0-3

Number of signal periods in the distance
from MP331
Input: 1 to 16 777 215

MP334.0-3

Distance between reference marks for
encoders with distance-coded reference
marks
Input:

0 to 65535 [grating periods]

0=1000 grating periods
(standard setting)