background image

4–64

TNC 370 D

Machine Parameters

July 02

4.8 Integrated PLC

Machine
parameter

Function and input

Change via

Reaction

MP4010

PLC program out of EPROM or RAM
Input: 0 or 1
0 = EPROM
1 = RAM

Reset

MP4020 PLC

compatibility

Input: %xxxxxxx
Bit 0
0 = non-compatible (marker range 4xxx)
1 = compatible (marker range 2xxx)
Bit 1 to 5 reserved
Bit 6
1 = PLC positions in the format
1/10000 mm; oriented spindle stop
triggered by module 9171 or by marker
M4130/D592 in the format 1/10000°

Reset

MP4060.0-3 Path-dependent

lubrication

Input:

0 to 99 999.9999 [mm]

PLC
RUN

MP4070

Compensation per PLC cycle for lag-
tracking error compensation
Input:

0.001 to 0.005 [mm]

PLC
RUN

MP4110.0-47 Time for Timer T0 to T47

Input:

0 to 65 535 [PLC cycles]

PLC
RUN

MP4120.0-31 Preset value for counter C0 to C31

Input:

0 to 65 535 [PLC cycles]

PLC
RUN

MP4130

MP4130.0

MP4130.1
MP4130.2

MP4130.3

MP4130.4

MP4130.5

Number the fast PLC inputs
Input:

0 to 255 [No. of the PLC input]

Fast PLC input for suppressing the
monitoring functions
No function
Fast PLC input sets M4590
(signal duration > 6 ms)
Fast PLC input sets M4591
(signal duration > 6 ms)
Fast PLC input sets M4592
(signal duration > 6 ms)
Fast PLC input sets M4593
(signal duration > 6 ms)