beautypg.com

6 operation with servo lag 4–60, 7 main, Spindle – HEIDENHAIN TNC 370D User Manual

Page 63: 6 operation with servo lag, 7 main spindle

background image

4–60

TNC 370 D

Machine Parameters

July 02

4.6 Operation with Servo Lag

Machine
parameter

Function and input

Change via

Reaction

MP1710.0-3

Position monitoring for control with servo
lag (erasable)
Input:

0.000 to 1 000.000 [mm]

Recommended: 1.2

· servo lag

PLC

MP1720.0-3

Position monitoring for control with servo
lag (EMERGENCY STOP)
Input:

0.000 to 1 000.000 [mm]

Recommended: 1.4

· servo lag

PLC

MP1810.0-3

k

v

factor for control with servo lag

Input:

0.100 to 10.000 [Fehler ]

!

PLC

MP1820.0-3

Multiplication factor for the kv factor
Input:

0.001 to 1.000

PLC

MP1830.0-3 Characteristic

kink

Input:

0.000 to 100.000 [%]

PLC


4.7 Main Spindle

Machine
parameter

Function and input

Change via

Reaction

MP3010

Output of rotational speed, gear range
Input:
0 = no output of spindle speed
1 = coded output of spindle speed, only if

the speed changes

2 = coded output of spindle speed on each

TOOL CALL

3 = analog output of spindle speed, but

gear change signal only if the speed
changes

4 = analog output of spindle speed, but

gear change signal on each TOOL
CALL

5 = analog output of spindle speed, but no

gear change signal

6 = same as input value 3 but with

controlled spindle for orientation

7 = same as input value 4 but with

controlled spindle for orientation

8 = same as input value 5 but with

controlled spindle for orientation

Reset

MP3020

Speed range for S code output
Input:

0 to 99 999

(with analog output of the spindle speed,
enter 1991 here)

PLC