3.7.13 Touch Trigger Probes


Any of the following touch trigger probes for workpiece measurement can be connected.

TS

220

Touch trigger probe with cable connection: for digitizing, workpiece setup and
workpiece measurement during machining


TS

630

Touch trigger probe with infrared transmission: for workpiece setup and workpiece

measurement during machining


X12 Touch Probe Input for Workpiece Measurement

Logic unit

D-sub terminal
(female) 15-pin

Assignment

1 0

V

3 Ready

4 Start

5

+15 V ± 10% (maximum 100mA)

6

+ 5 V ± 5% (maximum 100mA)

7

Battery warning

8

0 V (U

N

)

9 Trigger

signal

10

Trigger signal

1

2, 11 to 15

Do not use

Housing External

shield

1)

Stylus at rest means logic level High