beautypg.com

HEIDENHAIN TNC 370D User Manual

Page 41

background image


X48 Analog Input (PLC) at the LE

D-sub terminal
(female) 25-pin

Assignment

1 I

1

+ Constant current for Pt 100

2 I

1

– Constant current for Pt 100

3 U

1

+ Measuring input for Pt 100

4 U

1

– Measuring input for Pt 100

5 I

2

+ Constant current for Pt 100

6 I

2

– Constant current for Pt 100

7 U

2

+ Measuring input for Pt 100

8 U

2

– Measuring input for Pt 100

9

Do not use

10

Do not use

11

Do not use

12

Do not use

13

Do not use

14

Analog input 1 –10 V to +10 V

15

Analog input 1 0 V (reference potential)

16

Analog input 2 –10 V to +10 V

17

Analog input 2 0 V (reference potential)

18

Analog input 3 –10 V to +10 V

19

Analog input 3 0 V (reference potential)

20 to 25

Do not use

Housing External

shield

The correct polarity of analog inputs is essential.

X15, X16, X17, X18 Analog inputs on the PL 410 B

Terminal Assignment

1

–10 V to +10 V

2

0 V (reference potential)

3 Shield

3–38

TNC 370 D

Mounting and Electrical Installation

July 02