4–56
TNC 370 D
Machine Parameters
July 02
Machine
parameter
Function and input
Change via
Reaction
MP911.0-3
Positive software limit switch for traverse
range 2; Activation via PLC M4575 = 0,
M4574 = 1
Input: –30 000.000 to +30 000.000 [mm] or
[°] (Input values are referenced to the
machine datum)
PLC
MP912.0-3
Positive software limit switch for traverse
range 3; Activation via PLC: M4575 = 1,
M4574 = 0
Input: –30 000.000 to +30 000.000 [mm] or
[°] (input values referenced to machine
datum)
PLC
MP920.0-3
Negative software limit switch for traverse
range 1; Default setting after power-on;
activation via PLC M4575 = 0, M4574 = 0
Input: –30 000.000 to +30 000.000 [mm] or
[°] (input values referenced to the machine
datum)
PLC
MP921.0-3
Negative software limit switch for traverse
range 2; Activation via PLC M4575 = 0,
M4574 = 1
Input: –30 000.000 to +30 000.000 [mm] or
[°] (Input values referenced to the machine
datum)
PLC
MP922.0-3
Negative software limit switch for traverse
range 3; Activation via PLC: M4575 = 1,
M4574 = 0
Input: –30 000.000 to +30000.000 [mm] or
[°] (Input values referenced to the machine
datum)
PLC
MP950.0-3
Datum for positioning blocks with M92
Input: –30 000.000 to +30 000.000 [mm] or [°]
Values referenced to the machine datum
PLC
RUN
MP960.0-3 Machine
datum
Input: –30 000.000 to +30 000.000 [mm]
or [°]
Values referenced to scale reference point
Reset