Machine
parameter

Function and input

Change via

Reaction

MP911.0-3

Positive software limit switch for traverse
range 2; Activation via PLC M4575 = 0,
M4574 = 1
Input: –30 000.000 to +30 000.000 [mm] or
[°] (Input values are referenced to the
machine datum)

PLC

MP912.0-3

Positive software limit switch for traverse
range 3; Activation via PLC: M4575 = 1,
M4574 = 0
Input: –30 000.000 to +30 000.000 [mm] or
[°] (input values referenced to machine
datum)

PLC

MP920.0-3

Negative software limit switch for traverse
range 1; Default setting after power-on;
activation via PLC M4575 = 0, M4574 = 0
Input: –30 000.000 to +30 000.000 [mm] or
[°] (input values referenced to the machine
datum)

PLC

MP921.0-3

Negative software limit switch for traverse
range 2; Activation via PLC M4575 = 0,
M4574 = 1
Input: –30 000.000 to +30 000.000 [mm] or
[°] (Input values referenced to the machine
datum)

PLC

MP922.0-3

Negative software limit switch for traverse
range 3; Activation via PLC: M4575 = 1,
M4574 = 0
Input: –30 000.000 to +30000.000 [mm] or
[°] (Input values referenced to the machine
datum)

PLC

MP950.0-3

Datum for positioning blocks with M92
Input: –30 000.000 to +30 000.000 [mm] or [°]
Values referenced to the machine datum

PLC
RUN

MP960.0-3 Machine

datum

Input: –30 000.000 to +30 000.000 [mm]
or [°]
Values referenced to scale reference point