Mounting and Electrical Installation

TNC 370 D

3–15

3.7.6 Analog Nominal Value Output



Maximum loading of the analog outputs:

2 mA

Maximum capacitance:

2 nF



X8 Nominal Value Output

Logic unit

Connecting Cable

D-sub terminal
(female) 15-pin

Assignment D-sub

connector
(male) 15-pin

Color

1

Nominal value output 1

1

BN

2 Analog

input

2

BN/GN

3

Nominal value output 2

3

YL

4

Do not use 4

RD/BL

5

Nominal value output 3

5

PK

6

Do not use 6

GY/PK

7

Nominal value output 4

7

RD

8

Nominal value output 5

8

VI

9

0V Nominal value output 1

9

WH

10

0V Analog input

10

WH/GY

11

0V Nominal value output 2

11

GN

12

Do not use 12

13

0V Nominal value output 3

13

GY

14

0V Nominal value output 4

14

BL

15

0V Nominal value output 5

15

BK

Housing

External shield

Housing

External shield


· The connecting cables to the nominal value outputs must not have more than one intermediate

terminal.

· If it is necessary to branch to physically separate servo inputs, the connection must be

made in a grounded terminal box. Suitable terminal boxes are available from HEIDENHAIN
(Id. Nr. 251 249 01).

· The chassis of the terminal box must be electrically connected with frame of the machine.

· The 0 V connection of the nominal-value-difference inputs must be connected with signal

ground. Required cross section

³ Ø 6 mm².

· Use only original HEIDENHAIN connecting cables and connecting elements.