beautypg.com

Switch reference, Switch reference -41 – Grass Valley Performer SD User Manual

Page 73

background image

2-41

Installation Reference

Switch Reference

Table 2-6 lists potential settings and effects for switches used to
configure the Performer. The switches are located on the VAA
Board of the Performer switcher.

The table shows default settings in bold italic print. Address and
Starting Level default values are both zero (0). In the table, O = an

open

or

off

switch segment; C = a

closed

or

ON

switch segment.

For Switch 5, R = right direction; L = left direction.

Table 2-6.

Switch Reference, S1, 2, and 3 in Performer Switcher

Effect

Switch

Segments

1

2

3

4

5

6

7

8

7 Data Bits

S3

C

Selectable for ASCII and Model 200
protocols only. Other protocols are
always 8 data bits.

8 Data Bits

S3

O

300 Baud

S3

O

O

O

`

600 Baud

S3

O

O

C

1200 Baud

S3

O

C

O

2400 Baud

S3

O

C

C

4800 Baud

S3

C

O

O

9600 Baud

S3

C

O

C

19.2K Baud

S3

C

C

O

38.4K Baud

S3

C

C

C

76.8K Baud

S3

O

O

O

No Parity

S3

O

O

Even Parity

S3

O

C

Odd Parity

S3

C

O

VI Internal,
send external

S2

O

C

VI Internal,
don’t send
external

S2

O

O

VI S2

C

0

* 1. Address values are cumulative and are added into the total when the switch is in the
Closed (ON) position. In default 20-TEN compatible protocol, S1 is a source, destina-
tion, level offset determinant (see pages 2 - 54, 55, 56). Default address offset is 000.