162

Maestro Channel Branding User Guide

Section 5 — The Maestro Configuration Editor

Sub System

Select “Action.”

Purpose

“Transition in Progress” is the only choice when “MaestroGPO” is the
device type.

Trigger Type

“Level” is the only choice when “MaestroGPO” is the device type. When a
transition begins, the GPIO contact will go to the state selected in the
Trigger Sense column (described below).

Trigger Duration

This column is not used in this application.

Trigger Sense

Selections are:

High - close the contact when a transition begins and open when the
transition is complete, or

Low - open the contact when a transition begins and close when the tran-
sition is complete.

When finished configuring the table, select “

Apply

” or “

OK

.” The Name of

the GPIO Definition set will now appear in the set panel. The set is assigned
to the appropriate Maestro channel (Processor) using the Channel Setup
table.

Source Tally Mode

Source tally mode, also referred to as “stand-alone tally,” can be used for
either Encore- or Jupiter-controlled systems.

When the GPIO Definition table is first opened, the editor will open a set
panel. Create a name for the GPIO table, then select an Input set, and then
select “New.” (The table is assigned to a Maestro channel using the Channel
Setup table.) See

Figure 125

.

Note

Source Tally mode will not be available unless an Input Set Dependency is
applied to the GPIO Definition as illustrated in

Figure 125

.