beautypg.com

Grass Valley Maestro Master Control v.1.7 User Manual

Page 114

background image

110

Maestro Channel Branding User Guide

Section 5 — The Maestro Configuration Editor

Redundant IP Address

Enter the alternative IP address for the control system. For example:

Encore - enter the facility LAN (typically EN1) address of the redun-
dant Encore SCB (if any).

Jupiter control using serial connection - no entry.

Jupiter control using LAN connection - enter the IP address of the
redundant CM-4000.

Baud Rate

Enter the Baud rate for the Jupiter serial connection.

Encore - no entry.

Jupiter serial connection - select the baud rate for the Maestro “Router Con-
trol” port connection to the VM/CM serial port. The normal rate is “38400.”
This must agree with the VM/CM value established during Jupiter config-
uration.

Jupiter LAN connection - no entry.

Data Bits

Enter the Data bits for the Jupiter serial connection.

Encore - no entry.

Jupiter serial - select “8.”

Jupiter LAN - no entry.

Stop Bits

Enter the Stop bits for the Jupiter serial connection.

Encore - no entry.

Jupiter serial - select “1.”

Jupiter LAN - no entry.

Parity

Enter the Parity for the Jupiter serial connection.

Encore - no entry.

Jupiter serial - select “ODD.”

Jupiter LAN - no entry.