18

Setting Up Your Kaleido-Modular-X System

Physical Setup

FlexBridge wiring for a 48 × 4 system

To connect the input and output cards in a Kaleido-Modular-X 48 × 4

1 Complete the bridging for a 32 × 4 configuration (see

FlexBridge wiring for a 32 × 4

system

, above).

2 Bridge Input C to Input B, by connecting:

• INPUT C FLEXBRIDGE OUT A1 to INPUT B FLEXBRIDGE IN A1

• INPUT C FLEXBRIDGE OUT A2 to INPUT B FLEXBRIDGE IN A2

• INPUT C FLEXBRIDGE OUT B1 to INPUT B FLEXBRIDGE IN B1

• INPUT C FLEXBRIDGE OUT B2 to INPUT B FLEXBRIDGE IN B2

FlexBridge wiring for a 64 × 4 system

To connect the input and output cards in a Kaleido-Modular-X 64 × 4

1 Complete the bridging for a 48 × 4 configuration (see

FlexBridge wiring for a 32 × 4

system

, above).

2 Bridge Input D to Input C, by connecting:

• INPUT D FLEXBRIDGE OUT A1 to INPUT C FLEXBRIDGE IN A1

• INPUT D FLEXBRIDGE OUT A2 to INPUT C FLEXBRIDGE IN A2

• INPUT D FLEXBRIDGE OUT B1 to INPUT C FLEXBRIDGE IN B1

• INPUT D FLEXBRIDGE OUT B2 to INPUT C FLEXBRIDGE IN B2

INPUT B

INPUT A

OUTPUT A

OUTPUT B