Grass Valley Intuition XG v.5.0 User Manual
Page 83
5-20
Intuition XG Configuration Guide
Dashboard - Intuition XG’s Local Configuration Software
A
UTOMATION
M
ODE
: Determines the timestamping mechanism used for commands
between the Vertigo devices and Xplay.
•
D
ISABLED
: When selected the timestamp of the command will be ignored
and the command is executed immediately.
•
S
YSTEM
C
OUNTER
: High performance counter issued to reference the
time of the command.
•
S
YSTEM
C
LOCK
: Sets the format of the timestamps, which is timecode-
based (Hour: Minute: Seconds: Frames).
D
EAD
B
AND
: Sets the dead band zone for the time stamping of commands. If
the difference in timestamps between multiple commands is less than the
dead band, the earlier timestamp will be use for all commands.
P
REROLL
: Sets the preroll time by which all timestamps are adjusted. The
default value for this setting is 10 frames.
P
REROLL
M
ARGIN
: When the Vertigo devices receive automation commands,
they are usually timestamped. The devices add the preroll time as an offset to
these timestamps. The preroll margins is an additional offset added. The
preroll setting is an integer allowing only whole frames. The preroll margin
allows fractional values. The default value for this setting is 0.25 frames.
R
ENDER
P
ATHS
I
MAGES
: Specifies the directory path of where the image file will be saved to
when the S
NAPSHOT
command is used in Xbuilder.
C
LIPS
: Specifies the directory path of where the image file will be saved to
when the R
ENDER
TO
D
ISK
command is used in Xbuilder.
C
EL
A
NIMATIONS
C
ACHE
S
IZE
: Sets the number of cel animations that are cached in system
memory after they are no longer referenced by a loaded scene.
The default is 250. Increasing the cache size setting will unnecessarily slow
down performance and occupy memory space.
M
AX
S
IZE
: Specifies the maximum size of a cel animation that Intuition XG will
accept. Cel animations that are larger are rejected. The default is 250 MB.
D
EVICE
O
UTPUT
F
ILL
: Only the fill signal will be transmitted to the output monitor.
F
ILL
AND
K
EY
: The fill and key signals will be transmitted to the output
monitor/device. This setting is the default for Intuition XG devices.
I
NITIAL
K
EYER
S
TATE
Sets the initial state of the Vertigo device’s internal virtual keyer list.
O
N
: Sets the Vertigo device’s keyer to an active state. This is the default
setting.
O
FF
: Sets the Vertigo device’s keyer to an inactive state.
R
OLL
U
PDATE
I
NTERVAL
Determines if the vertical movement interval of a crawl is based on a F
IELD
or
F
RAME
.
P
ASSWORD
A simple security feature that allows you to set a password so that other users
cannot change the device settings.