DO

: To setup DI, please define the

Active level as 0 or 1. If the active level is set as 1, then

camera will change the output voltage to high when this response is activated by an event rule.

The voltage will go back to low when the event ends.

Interval determines the minimum

duration of each DO response( in seconds). DO will remain at the active level during this time,

and if another event triggers DO before the end of the first DO, the second trigger will no take

effect. 0 means there is no minimum duration.

Notification message

Notification messages

may be sent to either an email or a HTTP CGI server. If sent to a CGI

server, it works the same as an URL command, but it does not allow a second message at end of

event. You may configure up to three preset massages. You can configure a message, but

disable it. This will allow you to keep the settings without using it, which will be useful in testing

and troubleshooting.

*Pre-requisites: SMTP server / HTTP CGI server setup.

*Pre-requisites: SMTP server / HTTP CGI server setup.