Monitoring and Troubleshooting
Verilink Access System 2000: The Basics
5-15
Performance
Data Processing
The following sections list the data processing for the AT&T TR-
54016, ANSI TIM1.3, Verilink, and equipment-side performance
data.
NOTE: The NCC and TAC store part of the 24-hour performance
data in two separate register sets. One set is for the customer
(user) and the other set is for the other provider (telephone
company). Both the user and telephone company operators
can access and read the registers, but each can only reset
their own register sets. Only the TR-54016 registers are in
the carrier set.
AT&T TR 54016
Performance Data
Processing
The following AT&T performance data is stored in telephone
company registers on the application module:
•
LOFC Register
•
BES Register
•
UAS Register
•
SES Register
•
ES Register
•
24-hour Data Register (of all above data)
ANSI TIM1.3
Performance Data
Processing
The following ANSI TIM1.3 performance data is stored in user
registers on the application module:
•
ES-L Register
•
SEFS Register
•
SES Register
•
ES-B Register
•
LOSS Register
•
UAS Register
•
AISS Register
RAIS
•
•
Sending Yellow Alarm Indication Signal
Alarm
—
SEF
•
•
Severely Errored Framing Alarm
Alarm
—
SEFS
•
•
Severely Errored Framing Second
Performance
—
SES
•
•
Severely Errored Second
Performance
—
UAS
•
•
Unavailable Second
Performance
—
UASS
•
•
Unavailable Signal State
Performance
—
Acronym
T1
E1
Definition
Performance/
Alarm/Event/Flag
Class