Monitoring and Troubleshooting

Verilink Access System 2000: The Basics

5-15

Performance

Data Processing

The following sections list the data processing for the AT&T TR-
54016, ANSI TIM1.3, Verilink, and equipment-side performance
data.

NOTE: The NCC and TAC store part of the 24-hour performance

data in two separate register sets. One set is for the customer

(user) and the other set is for the other provider (telephone

company). Both the user and telephone company operators

can access and read the registers, but each can only reset

their own register sets. Only the TR-54016 registers are in

the carrier set.

AT&T TR 54016

Performance Data

Processing

The following AT&T performance data is stored in telephone
company registers on the application module:

LOFC Register

BES Register

UAS Register

SES Register

ES Register

24-hour Data Register (of all above data)

ANSI TIM1.3

Performance Data

Processing

The following ANSI TIM1.3 performance data is stored in user
registers on the application module:

ES-L Register

SEFS Register

SES Register

ES-B Register

LOSS Register

UAS Register

AISS Register

RAIS

Sending Yellow Alarm Indication Signal

Alarm

SEF

Severely Errored Framing Alarm

Alarm

SEFS

Severely Errored Framing Second

Performance

SES

Severely Errored Second

Performance

UAS

Unavailable Second

Performance

UASS

Unavailable Signal State

Performance

Acronym

T1

E1

Definition

Performance/

Alarm/Event/Flag

Class