Site Planning

Verilink Access System 2000: The Basics

3-3

T1 Network

Interface

Each NCC, SCC, and TAC must be within the following cable
distances from connected equipment:

655 feet (199 meters) maximum from DSX-1 equipment. This
distance determines the pre-equalization option setting
toward the equipment.

3000 feet (914 meters) maximum from the first repeater on the
network. This distance determines the network line build-out
option setting.

External Clock

Source

If an external clock is used to synchronize CSUs with DIUs. The
maximum permissible cabling distances to the clock source are:

150 feet (45 meters) with an external clock in an RS-422
format.

5 feet (1.5 meters) with an external clock in a TTL signal
format.

If an external RS-422 or TTL clock is connected to a TIU 2850, the
maximum cabling distances are the same as the external clock.

DTE Interface

The maximum cabling distance between an AS2000 data port and
your data terminal equipment depends on the type of interface.

250 feet (76 meters) for ITU-T V.35 operation.

200 feet (60 meters) maximum for EIA 530 or RS-422 operation
(decreases as data rate increase).

50 feet (15 meters) for HSSI.

NOTE: For long cable runs to DTE, use of TT timing is recommended.

System Power

Requirements

The AS2000 system uses a variety of power supplies that can
accommodate different commercial power sources. AS2000 system
components require a commercial power source free of surges and
other transient voltages. Commercial power requirements for the
AS2000 are listed in

Table 3-1

and

Table 3-2

.

Table 3-1 Multi-line Shelf Power Supplies

PAC 2910

110 Vac

50- to 60 HZ

75 Watts

15-amp circuit; separate branch

circuit for each AC power supply

PAC 2930

110 to 240

Vac

50 to 60 Hz

200 Watts

15-amp circuit; separate branch

circuit for each AC power supply

PDC 2920

48 Vdc

input

Separate fused

75 Watts

Associated battery return path for

each power supply; recommended

fuse size of 10-amp

PDC 2930

48 Vdc

input

Separate fused

200 Watts

Associated battery return path for

each power supply; recommended

fuse size of 10-amp