beautypg.com

Table 5.6, Status flags (register 30001), Table 5.7 – RLE LD2000 User Manual

Page 56: Status flags (register 30010), Table 5.8, Status flags (register 30011)

background image

www.rletech.com

56

970.484.6510

5

Modbus Communication

Table 5.6 Status Flags (Register 30001)

Bit

Description

00

1 = Leak is Detected

01

1 = Cable Break Alarm

02

1 = Contamination is detected

04-15

Spare

Table 5.7 Status Flags (Register 30010)

Bit

Description

00

1 = Zone1

01

1 = Zone2

02

1 = Zone3

03

1 = Zone4

04

1 = Zone5

05

1 = Zone6

06

1 = Zone7

07

1 = Zone8

Table 5.8 Status Flags (Register 30011)

Bit

Description

00

1 = Not enabled

01

1 = Enabled, b1=MBZ2

02

1 = MBZ3

03

1 = MBZ4

04

1 = MBZ5

05

1 = MBZ6

06

1 = MBZ7

07

1 = MBZ8

08

1 = MBZ9

09

1 = MBZ20

10

1 = MBZ11

11

1 = MBZ12

12

1 = MBZ13

13

1 = MBZ14