Installation
Set the LD2000's IP Address using an EIA-232 Connection
To use the EIA-232 interface:
1
Connect the EIA-232 port (P4) on the LD2000 to a terminal or PC running terminal
emulation software (HyperTerminal) with a 9-pin male-female straight through serial cable.
6
2. Set the appropriate communication port to 9600 baud, NO parity, 8 data bits, 1 stop
bit, (9600/N/8/1), and no software or hardware flow command.
7
Once the terminal emulation software starts, type ? and press Enter on the keyboard and the
Main Menu should appear. If the Main Menu does not appear, check the communication
settings and make sure the unit is powered on.
8
From the Main Menu type netcfg to select the Network Configuration Menu.
9
Enter the new IP address for the LD2000 by typing ip xxx.xxx.xxx.xxx where
xxx.xxx.xxx.xxx is the new IP address of the unit. Separate each field with a decimal point.
For example, type ip 10.0.0.50
The LD2000 erases a memory block and copies data to flash memory before rebooting.
The LD2000 IP address is now set and the LD2000 can be accessed through a Web
browser using the new IP address.
10
Repeat steps 8–9 to change the Subnet Mask and Def Route, if needed, using the commands
nm xxx.xxx.xxx.xxx to change the Subnet Mask and dg xxx.xxx.xxx.xxx to change the
default gateway.