beautypg.com

Remko hts – REMKO HTS 90 ALU User Manual

Page 72

background image

Limit temperature / bivalence point

Outdoor temperature where the secondary heating

appliance cuts in under bivalent operation.

Monovalent mode

In this mode, the heat pump is the sole heating

appliance in the building all year round. Monova-

lent mode is primarily used in combination with

brine/water and water/water heat pumps.

Noise

Noise is transmitted in media such as air or water.

Essentially there are two types of noise, airborne

sound and solid-borne sound. Airborne sound is

transmitted entirely via the air. Solid-borne sound

is transmitted in solid materials or liquids and is

only partially radiated as airborne sound. The

audible range of sound lies between 20 and

20,000 Hz.

Refrigerant

The working medium used in a refrigerant plant,

e.g. heat pump, is referred to as the refrigerant.

The refrigerant is a liquid which is used for thermal

transfer in a refrigeration plant and which is able to

absorb heat by changing its state at low tempera-

tures and low pressures. A further change of state

at higher temperatures and higher pressure serves

to dissipate this heat.

Refrigerating capacity

Heat flux extracted from the environment by the

evaporator (air, water or soil).

Regulations and guidelines

The erection, installation and commissioning of

heat pumps has to be undertaken by qualified spe-

cialist engineers. In doing so, various standards

and directives are to be observed.

Seal inspection

System operators are obliged to ensure the pre-

vention of refrigerant leakage in accordance with

the directive on substances that deplete the ozone

layer (EC 2037/2000) and the Regulation on Cer-

tain Fluorinated Greenhouse Gases (EC

842/2006). In addition, a minimum of one annual

service and inspection must be carried out, as well

as a sealing test for refrigerating plants with a

refrigerant filling weight over 3 kg.

Seasonal performance factor

The seasonal performance factor relates to the

ratio of heat content delivered by the heat pump

system to the supplied electrical energy in one

year. It may not be compared to the performance

number. The seasonal performance factor

expresses the reciprocal of the annual power input

factor.

Single energy-source mode

The heat pump covers a large proportion of the

required thermal output. On a few days per year an

electrical heating coil supplements the heat pump

under extremely low outdoor temperatures. Dimen-

sioning of the heat pump for air/water heat pumps

is generally based on a limit temperature (also

known as balance point) of approx. -5 °C.

Sound pressure level

The sound pressure level is a comparable charac-

teristic quantity for the radiated acoustic output of a

machine, for example, a heat pump. The noise

emission level at certain distances and acoustic

environments can be measured. The standard is

based on a sound pressure level given as a nom-

inal noise level.

Split AC unit

Design where one part of the device is positioned

outdoors and the other inside the building. Both

units are connected to each other by a refrigerant

pipe.

Storage tank

The installation of a hot-water storage tank is gen-

erally recommended in order to extend the running

time of the heat pump under low heat require-

ments. A storage tank is required for air/water heat

pumps in order to bridge off-periods.

REMKO HTS

72