REMKO HTS 90 ALU User Manual

Page 13

background image

Series

HTS 200

HTS 260

Usable limits, heating

°C

-20 - +45

Service limits, cooling

°C

+15 - +45

Refrigerant / pre-charge quantity indoor module

-- / kg

R 410A

2)

/ 5.40

Refrigerant / pre-charge quantity

for more than 7 m length of ordinary pipe

g / m

60

Refrigerant connections on outdoor module

Inches (mm)

3/8" (9.52) / 5/8" (15.9)

Refrigerant connections on indoor module

Inches (mm)

1/2" (12.70) / 3/4" (19.05)

Refrigerant piping length, total

(simple length)

m

25

25

Refrigerant piping height, max.

m

15

15

Power supply indoor module

V / Ph / Hz

400V /3 Ph/ 50Hz

Power supply to indoor module control unit

V / Ph / Hz

230V /1 Ph/50Hz

Power supply to electrical heating coil

V / Ph / Hz

400V /3 Ph/ 50Hz

Max. current consumption

A

10.2

14.4

Rated current consumption for A7/W35

A

5.12

8.11

Rated power consumption for A7/W35

kW

3.10

4.15

Rated power consumption for A2/W35

kW

3,07

4,56

Max. power consumption

kW

6.39

8.45

Power factor at A7/W35 (cosφ)

--

0.8

0.8

Customer's fuse protection indoor module

A slow-

acting

3 x 16

3 x 20

Rated water flow (according to EN 14511, at ∆t 5 K)

m³/hr

2.6

3.5

Pressure loss on condenser at rated volumetric flow rate

bar

0.21

0.23

Pressure loss, outdoor

kPa

80

Airflow volume outdoor module

m³/hr

5,000

5400

Max. operating pressure, water

bar

3

Hydraulic connection, supply / return

Inches

1 1/4" AG

Recommended pipe dimension Cu copper

mm

35

42

Water volume, indoor module

l

5.3

5.3

Refrigerant oil

Type

Synthetic Oil FV50S

Rated power intake of indoor module pump, min./max.

W

7 / 136

Rated input power of each outdoor module fan

W

115

125

Rated power intake of indoor module pump, min./max.

A

0.07 / 1.03

Volumetric flow rate of indoor module pump, min./max.

m³/hr

0.9/2.8

0.9/3.5

Motor protection, indoor module pump

--

Resistant to blocking current

13