REMKO HTS 90 ALU User Manual

Page 61

background image

ID

Description

Desig

.

Details

ID7231 Anti-freeze protection

(I/O 2)

The anti-freeze protection in the heat pump's heat exchanger

was triggered due to an inlet temperature of less than 5°C.

After eliminating the cause of the error, the controller must be

restarted to reset the error

ID7236

Open contact - mix.

heating cycle inlet

temp. probe

S12

Open contact - mixed heating cycle inlet temperature probe

ID7237

Short circuit - mix.

heating cycle inlet

temp. probe

S12

Short circuit - mixed heating cycle inlet temperature probe

ID7238

Open contact - mix.

heating cycle return

temp. probe

S11

Open contact - mixed heating cycle return temperature probe

ID7239

Short circuit - mix.

heating cycle return

temp. probe

S11

Short circuit - mixed heating cycle return temperature probe

ID7250 Min. medium flow rate

(I/O 2)

The medium flow rate fell below the heat pump's minimum

medium flow rate due to defrosting or in cooling mode. After

eliminating the cause of the error, the controller must be

restarted to reset the error

ID7251 Min. volumetric flow

rate

The medium flow rate fell below the heat pump's minimum

medium flow rate due to defrosting or in cooling mode. After

eliminating the cause of the error, the indoor and outdoor units

must be restarted to reset the error

ID7252 Heat pump

malfunction code

S20

Heat pump malfunction code

ID7253 Heat pump 2

malfunction code

S20.2 Heat pump 2 malfunction code

ID7254 General inverter fault

General inverter fault - please contact an authorised service

technician

ID7255 EEPROM error

EEPROM error. Please contact an authorised service techni-

cian

ID7256 Envelope fault

Envelope fault - the compressor operates outside the pro-

grammed curve. Please contact an authorised service techni-

cian

ID7257 Fan overload

The compressor is disabled due to a fan overload

ID7258 Maximum hot gas tem-

perature

Maximum hot gas temperature - the compressor is blocked by

having reached the maximum hot gas temperature

ID7259 High pressure malfunc-

tion

High pressure malfunction. If this fault occurs frequently, please

contact an authorised service technician

ID7260 High pressure malfunc-

tion transducer

The compressor is disabled due to a high pressure malfunction

ID7262 Fault with probe B2

Fault with probe B2 - Please check probe B2 and the connec-

tion to the inverter board

ID7264 Fault with probe B4

Fault with probe B4 - Please check probe B4 and the connec-

tion to the inverter board

61