Remko hts – REMKO HTS 90 ALU User Manual
Page 62
ID
Description
Desig
.
Details
ID7267 Fault with probe B7
Fault with probe B7 - Please check probe B7 and the connec-
tion to the inverter board
ID7269 Fault with probe B9
Fault with probe B9 - Please check probe B9 and the connec-
tion to the inverter board
ID7270 Fault with probe B10
Fault with probe B10 - Please check probe B10 and the con-
nection to the inverter board
ID7271 Fault with probe B11
Fault with probe B11 - Please check probe B11 and the con-
nection to the inverter board
ID7272 Fault with probe B12
Fault with probe B12 - Please check probe B12 and the con-
nection to the inverter board
ID7273 WKF fault code E101
Communication error between com. kit and outdoor unit. F1/F2
twisted or cable break
ID7274 WKF fault code E177
Compressor stopped due to an emergency stop signal. After
eliminating the cause of the error, the indoor and outdoor units
must be restarted to reset the error
ID7275 WKF fault code E221
Short circuit or open contact - probe ambient air temperature
motherboard outdoor unit CN43 Pin 1&2
ID7276 Restart required
Due to the changed system (setting / coding resistor), the con-
troller has to be restarted - disconnect it from the power supply
for around 10 seconds
ID7278 Low overheating
The compressor is disabled due to overheating being too low.
ID7283 Open contact - internal
return temp. probe
S15
Open contact - internal return temperature probe
ID7284
Short circuit - internal
return temperature
probe
S15
Short circuit - internal return temperature probe
ID7285 Low suction gas
temperature
The compressor is disabled due to the suction gas temperature
being too low
ID7286 Coding error
Rc
A unique unit identifier could not be assigned using the coding
resistor at the Rc terminal
ID7287 Low evaporation tem-
perature
The compressor is disabled due to the evaporation temperature
being too low
ID7288 High evaporation tem-
perature
The compressor is disabled due to the evaporation temperature
being too high
ID7289 High condensation tem-
perature
The compressor is disabled due to the condensation tempera-
ture being too high
ID7290 WKF fault code E102
Communication error between com. kit and outdoor unit. F1/F2
twisted or cable break
ID7291 WKF fault code E201
Communication error between com. kit and outdoor unit - com-
munication could not be established or incorrect board version
ID7292 WKF fault code E231
Short circuit or open contact - evaporator temperature probe
motherboard outdoor unit CN43 Pin 3&4
ID7293 WKF fault code E251
Short circuit or open contact - hot gas temperature probe moth-
erboard outdoor unit CN43 Pin 5&6
REMKO HTS
62