frost proof. The outdoor module consists only of

the plate condenser, the fan and the fan motor.

This means that the outdoor unit is considerably

smaller. The indoor module contains the con-

denser of the refrigerant circuit, an electronic

expansion valve, filter dryer, refrigerant chamber

and connections for the heating network.

REMKO inverter technology

The heat pump's compressor is equipped with are

equipped with a speed control system, as needed.

The power control on conventional heat pumps

provides only two states, either ON (full output) or

OFF (no output). The heat pump turns on below a

specified temperature and turns off when this tem-

perature is reached. This kind of heat regulation is

very inefficient. Heat regulation in the REMKO

inverter heat pump is modulated to the actual need

and is adjusted to suit actual needs. The elec-

tronics system has an integrated frequency-con-

verter which serves to modify the condenser speed

and the speed of the blower as required. The con-

denser works at a higher speed when under full

load than under partial load. The lower speeds

ensure a longer operational lifetime for the compo-

nents, improved coefficient of performance and

lower noise. Lower speeds also result in lower

energy consumption (electricity) and longer service

life. i.e.: inverter heat-pumps will run practically

throughout the heating season. In all, the highest

efficiency possible.

1/3

When it is switched on, the inverter only requires
one-third of the time of conventional systems

Time

Minimal temperature fluctuations
mean energy savings

Conventional
Inverter

Temperature

Fig. 10: Modern inverter technology

REMKO HTS