Usable limits, heating

°C

-20 - +45

Service limits, cooling

°C

+15 - +45

Refrigerant / pre-charge quantity indoor module

-- / kg

R 410A

2)

/

1.75

R 410A

2)

/

2.95

Refrigerant / pre-charge quantity

for more than 7 m length of ordinary pipe

g / m

30

Refrigerant connections on outdoor module

Inches (mm)

3/8" (9.52) / 5/8" (15.9)

Refrigerant connections on indoor module

Inches (mm)

3/8" (9.52) / 5/8" (15.9)

Refrigerant piping length, total

(simple length)

m

30

50

Refrigerant piping height, max.

m

10

30

Power supply indoor module

V / Ph / Hz

230V /1 Ph/

50Hz

400V /3 Ph/

50Hz

Power supply to indoor module control unit

V / Ph / Hz

230V /1 Ph/50Hz

Power supply to electrical heating coil

V / Ph / Hz

400V /3 Ph/ 50Hz

Max. current consumption

A

12.2

7.3

Rated current consumption for A7/W35

A

6.5

4.08

Rated power consumption for A7/W35

kW

1.43

2.08

Rated power consumption for A2/W35

kW

1,49

1,99

Max. power consumption

kW

2.52

4.21

Power factor at A7/W35 (cosφ)

--

0.9

0.8

Customer's fuse protection indoor module

A slow-

acting

16

3 x 16

Rated water flow (according to EN 14511, at ∆t 5 K)

m³/hr

1.25

1.79

Pressure loss on condenser at rated volumetric flow rate

bar

0.17

0.25

Pressure loss, outdoor

kPa

80

Airflow volume outdoor module

m³/hr

2700

Max. operating pressure, water

bar

3

Hydraulic connection inlet/return flow, flat-sealing

Inches

1"

Recommended pipe dimension Cu copper

mm

28

Water volume, indoor module

l

4.2

4,8

Refrigerant oil

Type

Synthetic Oil FV50S

Rated power intake of indoor module pump, min./max.

W

7 / 136

Rated input power of each outdoor module fan

W

125

125

Rated power intake of indoor module pump, min./max.

A

0.07 / 1.03

Volumetric flow rate of indoor module pump, min./max.

m³/hr

0.9/2.0

0.9/2.0

Motor protection, indoor module pump

--

Resistant to blocking current

REMKO HTS

10