beautypg.com

OWON MSO Series User Manual

Page 90

background image

85

display setting, threshold setting and trigger setting. And it is possible to save 10 groups of
settings. Waveform storage and setting storage menu display as

Fig.5-73

.

Fig.5-73

.:Storage menu

Storage menu instruction as below:

Function

Setting

Instruction

Memory

SEL

Waveform

Setups

Waveform for storage or recall
Setups for storage or recall

Memory

ID

Waveform0~Waveform3

Setups 0~Setups 9

Storage 4 groups of waveform
Storage 10 groups of setups

Save

Save current waveform/setting in designated
No.

Recall

Recall waveform/ setups in designated No.

For example, to set "WAVE 0" in memory ID to save current waveform and "setting

0" to save current setting. Follow up below steps:

1. Press "C(SAVE/REL)" after data acquisition finished and storage menu appears
2. Press "F1" till storage display as "Waveform"
3. Press "F2" till memory ID. Display as "Waveform 0"
4. Press "F3" to save current display waveform. Info window will show "Waveform

saving" then show as "Waveform saved successfully" when storage finished.

5. Press "F1" till memory SEL as "Setups"
6. Press "F2" till memory ID. display as "Setups 0"
7. Press "F3" to save current various settings. Info window show "Setting saved

successfully".

8. Press "F4" to recall the memory waveform or settings (refer to

Fig.5-7

4)