OWON MSO Series User Manual
Page 107
102
Horizontal
System
Sampling rate range
1S/s~1GS/s half channel*,
1S/s~500MS/s each channel
---- MSO7062TD, 7102TD
1S/s~2GS/s half channel*,
1S/s~1G S/s each channel
----MSO8102T, 8202T
Interpolation
(sin x)/x
Record length
2M points on each channel
Scanning speed(S/div)
2ns/div~100s/div, step by 1~2~5
----MSO7062TD, 7102TD, 8102T
1ns/div~100s/div, step by 1~2~5
---- MSO8202T
Sampling rate / relay
time accuracy
±100ppm
Interval(△T )accuracy
(DC~100MHz)
Single
:
±(1 interval
time+100ppm×reading+0.6ns);
Average>16 : ±(1 interval time
+100ppm×reading+0.4ns)
Vertical system
A/D converter
8 bits resolution (2 Channels
simultaneously)
Sensitivity
2mV/div~10V/div(at BNC)
Displacement
±1V(2mV ~ 50mV), ±10V(100mV ~
1V), ±100V(2V~10V)
Analog bandwidth
60MHz----MSO7062TD
100MHz----MSO7102TD,MSO8102T
200MHz----MSO8202T
Single bandwidth
Full bandwidth
Low Frequency
≥10Hz (at input, AC coupling, -3dB)