beautypg.com

OWON MSO Series User Manual

Page 48

background image

43

mode is used to observe two unrelated signals. You can choose different trigger modes
for different channels. The options are as follows: edge, video, pulse or slope.

Alternate trigger(Trigger mode: Edge)

Alternate trigger(Trigger Type: Edge)

Menu is shown as

Fig.5-23

.

Fig.5-23 Alternate trigger(Trigger Type: Edge) Menu

Alternate trigger(Trigger Type: Edge)

Menu

list:

MENU

SETTING

INSTRUCTION

Source

CH1
CH2

Channel 1 as the trigger source.
Channel 2 as the trigger source.

Mode

Edge

Set vertical channel trigger type for edge trigger.

Slope

Rising

Falling

Trigger on the rising edge.
Trigger on the falling edge.

Coupling

AC
DC

HF

LF

Block the direct current component.
Unblock all components.
Block the high-frequency signal and only unblock the
low-frequency component.
Block the low-frequency signal and only unblock the high
-frequency component.

Holdoff

100ns~10s

Set interval by using TRIG LEVEL control, value range
from 100ns~10s.

Holdoff

Reset

Reset hold time to 100ns

Alternate trigger(Trigger Mode: video)

Alternate trigger(Trigger Type: video) Me

nu is shown as

Fig.5-24

.