beautypg.com

Logic analyzer – OWON MSO Series User Manual

Page 109

background image

104

displacement

Trigger Holdoff

range

100ns~10s

50% level

setting(typical)

Input signal frequency ≥50Hz

Edge trigger

slope

Rising、Falling

Sensitivity

0.3div

Pulse trigger

Trigger condition

Positive pulse:>、<、=
negative pulse:>、<、=

Pulse Width
range

24ns~10s

Video Trigger

Modulation

Support standard NTSC、PAL and SECAM
broadcast systems

Line number
range

1-525 (NTSC) and 1-625 (PAL/SECAM)

Slope Trigger

Trigger condition

Positive pulse:>、<、=
negative pulse:>、<、=

Time setting

24ns~10s

Alternate Trigger

Trigger on CH1

Edge, Pulse, Video, Slope

Trigger on CH2

Edge, Pulse, Video, Slope

Logic analyzer

Sampling rate

20 S/s ~ 1GS/s

Input channel

16

Max Storage

4M/Channel,16K(

when only

sampling rate is 250MS/s,

500 MS/s,1GS/s)

Measurement bandwidth

100MHz---- MSO7062TD,MSO7102TD,MSO8102T
200MHz---- MSO8202T

Input impedance

660K

Ω ±5%// 15±5pF

Threshold level

-6V~6V

Input signal range

-30V~30V

Trigger position setting

Pre-trigger, mid-trigger, re-trigger

Trigger Mode

Edge trigger, Bus trigger, Pattern trigger, Sequential

queue data ,Distributed queue trigger, Data width queue

trigger

Data Search

Support