Technical specifications, Digital storage oscilloscope – OWON MSO Series User Manual
Page 106
101
8. Technical Specifications
Unless otherwise specified, the technical specifications applied are applicable to the
probe with the attenuation switch setting 10X and the MSO series digital oscilloscope.
Only if the oscilloscope fulfill the following two conditions at first, can these
specification standards be reached.
This instrument should run for more than 30 minutes continuously under the
specified operating temperature.
If the change range of the operating temperature is up to or exceeds 5℃, open the
system function menu and execute the "Auto-calibration" procedure.
All specification standards can be fulfilled, except one(s) marked with the word
"Typical".
Digital Storage Oscilloscope
Performance Characteristics
Instruction
Bandwidth
60MHz----MSO7062TD
100MHz----MSO7102TD,MSO8102T
200MHz----MSO8202T
Channel
2 + 1 (External)
Acquisition:
Mode
Normal, Peak detect, Averaging
Sample rate (real time)
1GS/s half channel*, 500MS/s each
channel----MSO7062TD, 7102TD
2GS/s half channel*, 1GS/s each
channel----MSO8102T, 8202T
Input:
Input coupling
DC, AC , Ground
Input impedance
1MΩ±2%,in parallel with 15pF±5pF
Probe attenuation factor
1X,10X,100X,1000X
Max. input voltage
400V (PK-PK) (DC + AC PK-PK)
Bandwidth limit
20MHz、100MHz
Channel isolation
50Hz: 100 : 1
10MHz: 40 : 1
Time delay between
channel(typical)
150ps