Digital Storage Oscilloscope

Performance Characteristics

Instruction

Bandwidth

 60MHz----MSO7062TD
 100MHz----MSO7102TD,MSO8102T
 200MHz----MSO8202T

Channel

2 + 1 (External)

Acquisition

Mode

Normal, Peak detect, Averaging

Sample rate (real time)

 1GS/s half channel*, 500MS/s each

channel----MSO7062TD, 7102TD

 2GS/s half channel*, 1GS/s each

channel----MSO8102T, 8202T

Input

Input coupling

DC, AC , Ground

Input impedance

1MΩ±2%,in parallel with 15pF±5pF

Probe attenuation factor

1X,10X,100X,1000X

Max. input voltage

400V (PK-PK) (DC + AC PK-PK)

Bandwidth limit

20MHz、100MHz

Channel isolation

50Hz: 100 : 1

10MHz: 40 : 1

Time delay between

channel(typical)

150ps