V - View Configuration
SYNTAX
Vval
View (but not load) configuration
val
, where
val =
value from
0
to
100
.
DESCRIPTION
The View Configuration (
V
) command is used to look at a configuration previously-saved without loading it for use as
the present configuration. In response to this command, the Digital488/80A returns a string in the following format:
S###C#F#G#I###K#M###P#R#Y#D0000000000Z
where each
#
equals the option for that command saved in
the requested configuration. Data between the
D
and the
Z
are dependent upon the state of the I/O lines at the time
when the configuration was saved.
EXAMPLE
PRINT#1,"CLEAR08"
Line 1: Reset the Digital488/80A.
PRINT#1,"OUTPUT08;V18X"
Line 2: View configuration 18.
INPUT#2,A$,
PRINT A$
Line 4: Display is:
S018C5F2G2I000K1M016P0R1Y2D0000000000Z
where this message is interpreted as follows:
•
S018
- Saved configuration 18.
•
C5
- All 5 ports are outputs.
•
F2
- ASCII binary data format.
•
G2
- Only output port data sent when addressed to Talk.
•
I000
- Data lines are active high.
•
K1
-
EOI
disabled.
•
M016
-
SRQ
on Ready.
•
P0
- All 5 ports are selected.
•
R1
- Data is latched on an EDR transition.
•
Y2
- Bus terminator is
CR
only.
•
D0000000000Z
- All I/O lines are active low.
72 Digital488/80A Commands