CAUTION

Because the Configuration (C) command is used, the following programming
example(s) will not work properly if the HVCX1 option is installed with a conflicting
hardware configuration. To be safe, remove the HVCX1 board and replace it with the
jumper board to run the example(s).

EXAMPLE 5: Command Conflict Error.

PRINT#1,"OUTPUT08;G0C5P1X"

Line 1: Configure all 5 ports as outputs; select Port 1 only.

PRINT#1,"OUTPUT08;D123456ZX"

Line 2: Send too much data for one port.

PRINT#1,"OUTPUT08;E?"

Line 3: Query the error status (ERROR LED should be on).

PRINT#1,"ENTER08",

INPUT#2,A$,

PRINT A$

Line 6: Display shows:

E3-Conflict Error

(ERROR LED should

be off).