3 access, Draco tera 80 – IHSE USA 480c Series Draco tera compact User Manual
Page 80

Draco tera
80
2013-08-14
Pos: 63 /806-IHSE/Konfiguration/Systemeinstellung/480-xx/Zugang @ 7\mod_1309938080446_6.doc @ 53086 @ 3 @ 1
5.4.3 Access
The access configuration is set in this menu.
You have the following possibilities to access the menu:
You can select between the following settings:
Field
Selection
Description
activated
The user has to login with a user name
and a password once to enter OSD.
Thereafter the user remains logged in
until he explicitly logs out or an auto
logout is effected.
Note: When using the function Force
User Login, console favorites and
console macros still remain active.
Force User
Login
deactivated Function not active (default)
activated
CPU access is restricted according to
the permissions in the ACL (Access
Control List).
User login is required.
Switching by keyboard 'Hot Keys'
requires a prior login.
Enable User
ACL
deactivated Function not active (default)
activated
CPU access is restricted according to
the permissions in the respective
Console ACL (Access Control List). No
login required
Enable
Console ACL
deactivated Function not active (default)
activated
Newly created users automatically
receive access to all CPUs
Enable new
User
deactivated Function not active (default)
activated
Newly created CON devices
automatically receive access to all CPUs
Enable new
CON
deactivated Function not active (default)
Auto
Disconnect
activated
Upon opening the OSD, the console will
be automatically disconnected from the
current CPU.