beautypg.com

7 specifications, 1 interfaces, 1 rj45 (network) – IHSE USA 480c Series Draco tera compact User Manual

Page 178: 2 rj45 (serial), 3 rj45 (interconnect), 1 rj45, Network), 2 rj45, Serial), 3 rj45

background image

Draco tera

178

2013-08-14

7 Specifications

Pos: 126 /806-IHSE/Technische Daten/Schnittstellen/UEB_Schnittstellen @ 5\mod_1278578201870_6.doc @ 42114 @ 2 @ 1

7.1

Interfaces

Pos: 127 /806-IHSE/Technische Daten/Schnittstellen/RJ45 (Netzwerk) @ 7\mod_1309942049133_6.doc @ 53692 @ 3 @ 1

7.1.1 RJ45 (Network)

The communication of the Cat X devices requires a 1000BASE-T
connection.

The cabling has to be done according to EIA/TIA-568-B (1000BASE-T)
with RJ45 connectors at both ends. All of the four wire pairs are used in
both directions. The cabling is suitable for a full duplex operation. For the
cable connection to a source (computer, CPU), a crossed network cable
(cross cable) has to be used.


Pos: 128 /806-IHSE/Technische Daten/Schnittstellen/RJ45 (seriell) @ 8\mod_1345795550934_6.doc @ 68062 @ 3 @ 4

7.1.2 RJ45 (Serial)

The communication takes place with a transmission speed of
115.2 KBaud, regardless of the file format. The transmission takes place
with eight data bits and a stop bit, but without a parity bit. Limited
hardware handshake (DSR) is possible.

Pos: 129 /806-IHSE/Technische Daten/Schnittstellen/RJ45 (Gerätekommunikation) @ 5\mod_1278578339308_6.doc @ 42186 @ 3 @ 1

7.1.3 RJ45 (Interconnect)

The communication of the Cat X devices requires a 1000BASE-T
connection.

Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with
RJ45 connectors at both ends. All four cable wire pairs are used.


Pos: 130 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1