8 console settings, 1 con devices, 8 console – IHSE USA 480c Series Draco tera compact User Manual
Page 114: Settings, 1 con, Devices, Draco tera 114

Draco tera
114
2013-08-14
5.8
Console Settings
You have the possibility to perform the following console settings:
Pos: 78 /806-IHSE/Konfiguration/480_Konsolen-Einstellungen/480-xx/CON Devices @ 7\mod_1309938548274_6.doc @ 53254 @ 3 @ 1
5.8.1 CON Devices
New CON devices are created in this menu including access rights and
assignment to extenders.
You have the following possibilities to access the menu:
You can select between the following settings:
Field
Selection
Description
ID
Text
ID of the CON unit (see Chapter 5.4.2,
Page 77).
Name
Text
Name of the CON device.
activated
Create new CON device as a virtual
one.
Virtual Device
deactivated
Function not active (default).
activated
Allow activation of the User ACL at the
local console.
Allow User
ACL
deactivated
Function not active (default).
activated
Force user login at this CON device.
Force Login
deactivated
Function not active (default).
activated
When losing the video signal
between source (computer, CPU)
and the CPU unit or when losing
the connection between the matrix
and the CON unit, there will be
displayed an orange frame.
When switching to a CPU without
video signal, a blank screen will
appear surrounded by an orange
frame.
LOS Frame
deactivated
Function not active (default).