beautypg.com

Draco tera 164 – IHSE USA 480c Series Draco tera compact User Manual

Page 164

background image

Draco tera

164

2013-08-14

1. Select in the list CON Devices on the left side that one that should be

switched to a CPU device and open it by pressing .

2. Select in the list CPU Devices on the left side that one that should be

connected to the open CON device.

3. Confirm with the respective keyboard command according to the

desired connection type.

Switching operations from the own CON device can only be done to CPU
devices that are available in the list CPU Devices.

The following information is shown in this menu:

Field

Description

CON device

Assigned physical extender unit (CON unit)

CON assigned Virtual CON Device that is assigned to the real

CON device

CPU connected Currently connected CPU device
CON status

Current connection status (CON device)

EXT list

List of all available physical extender units
(CON units)

CPU device

Assigned physical extender unit (CPU unit)

CPU assigned

Real CPU device that is assigned to a virtual
CPU device

CON
connected

Currently connected CON device

CPU status

Current connection status (CPU device)

EXT list

List of all available physical extender units
(CPU units)

You can select between the following switching functions:

Function

Keyboard Command

Set a video only connection.

Set a KVM connection.

Set a KVM connection in private mode (video
sharing disabled).

+

Disconnect own CON device from CPU device.