9 mtbf, Draco tera 186 – IHSE USA 480c Series Draco tera compact User Manual
Page 186

Draco tera
186
2013-08-14
7.9
MTBF
The following table contains the mean time between failure (MTBF) in
power-on hours (POH). The estimate is based on the FIT rates of the
parts included. FIT rates are based on normalized environmental
conditions of T = 60°C and activation energy (E
a
) of 0.7 eV. Calculations
are based on 90% confidence limit.
We estimate that inside the housing, temperature will be 15°C higher than
the ambient temperature. Therefore, the MTBF calculation refers to an
ambient temperature of 45°C. The humidity is limited to 60%.
Matrix
Chassis
Per Fan
Per PSU
Draco tera 80C
90,690 280,000 238,800
Draco tera 48C32F
87,250 280,000 238,800
Draco tera 64C
97,300 280,000 238,800
Draco tera 48C16F
95,600 280,000 238,800
Draco tera 48C
140,000 280,000 295,700
Draco tera 32C
165,300 280,000 295,700
Draco tera 16C
208,322 280,000 295,700
Draco tera 8C / 8F
684,700 280,000 309,700