7.9

MTBF

The following table contains the mean time between failure (MTBF) in
power-on hours (POH). The estimate is based on the FIT rates of the
parts included. FIT rates are based on normalized environmental
conditions of T = 60°C and activation energy (E

a

) of 0.7 eV. Calculations

are based on 90% confidence limit.

We estimate that inside the housing, temperature will be 15°C higher than
the ambient temperature. Therefore, the MTBF calculation refers to an
ambient temperature of 45°C. The humidity is limited to 60%.

Matrix

Chassis

Per Fan

Per PSU

Draco tera 80C

90,690 280,000 238,800

Draco tera 48C32F

87,250 280,000 238,800

Draco tera 64C

97,300 280,000 238,800

Draco tera 48C16F

95,600 280,000 238,800

Draco tera 48C

140,000 280,000 295,700

Draco tera 32C

165,300 280,000 295,700

Draco tera 16C

208,322 280,000 295,700

Draco tera 8C / 8F

684,700 280,000 309,700