Connecting the wires in the junction box, Testing/checking operation, 3 set the voltmeter to read ohms – Gasboy M06245K0XX User Manual
Page 21: Completing the installation
MDE-4506A Atlas™ Pulser Kits M06245K0XX Installation · May 2006
Page 21
Installing the Pulser Kit in Single Unit and 9140 (Kits M06245K004 through M06245K007 and M06245K009 - M06245K011)
5
Place the pulser in position by positioning the conduit mounted on the pulser through the slot
in the unit. Ensure that the pinned shaft on the pulser aligns with the center hole in the idler
gear and the pin seats in the slot in the gear. The mounting holes in the mounting plate must
align with the holes in the spacers. Refer to
.
6
Loosely secure in place with two washers and two screws.
7
After careful examination to ensure that the parts are meshed properly, tighten the screws.
8
Ensuring that the wires extend through the conduit, make the necessary connections as shown
in
.
9
Ensure that the wires extend into the junction box.
Connecting the Wires in the Junction Box
1
Remove the screws securing the cover on the junction box. Save screws for remounting.
2
Inside the junction box, connect the green ground lead from the pulser to a secure known
ground.
3
Refer to your Fuel Management System installation manual for proper wiring of the pulsers.
4
Remount the junction box cover and secure with the screws removed in
Testing/Checking Operation
Only the 10:1 pulser can be tested for operation. Using test equipment, others must be tested
when hooked to the pump/dispenser controller. Test the 10:1 pulser as follows:
1
Inform the manager/owner that power will be restored to the unit and then restore power to the
unit.
2
Connect a mechanical voltmeter on the two orange signal wires.
3
Set the voltmeter to read Ohms.
4
Slowly dispense fuel and observe that the needle deflects upscale for each 1/10 gallon fuel.
Completing the Installation
1
After determining that the pulser is functioning properly, remount the dial faces on the
computer and secure them with the screws saved during removal.
2
Remount the bezels on both sides of the unit and secure them with the screws saved during
removal.
3
Remount the doors on both sides of the unit and secure them with the keylocks.
4
Inform the manager/owner that the unit can be returned to service.