beautypg.com

Connecting the wires in the junction box, Testing/checking operation, 3 set the voltmeter to read ohms – Gasboy M06245K0XX User Manual

Page 19: Completing the installation

background image

MDE-4506A Atlas™ Pulser Kits M06245K0XX Installation · May 2006

Page 19

Installing the Pulser Kit in Single Unit and 9140 (Kits M06245K004 through M06245K007 and M06245K009 - M06245K011)

6

Loosely secure in place with two washers and two screws.

7

Ensure that the parts are meshed properly and tighten the screws.

8

Ensuring that the wires extend through the conduit, make the necessary connections as shown
in

Figure 9 on page 17

or

Figure 10

.

9

Ensure that the wires extend into the junction box.

Connecting the Wires in the Junction Box

1

Remove the screws securing the cover on the junction box. Save screws for remounting.

2

Inside the junction box, connect the green ground lead from the pulser to a secure known
ground.

3

Refer to your Fuel Management System installation manual for proper wiring of the pulsers.

4

Remount the junction box cover and secure it with the screws removed in

step 1

.

Testing/Checking Operation

Only the 10:1 pulser can be tested for operation. Using test equipment, others must be tested
when hooked to the pump/dispenser controller. Test the 10:1 pulser as follows:

1

Inform the manager/owner that power will be restored to the unit and then restore power to the
unit.

2

Connect a mechanical voltmeter on the two orange signal wires.

3

Set the voltmeter to read Ohms.

4

Slowly dispense fuel and observe that the needle deflects upscale for each 1/10 gallon fuel.

Completing the Installation

1

After determining that the pulser is functioning properly, remount the dial faces on the
computer and secure them with the screws saved during removal.

2

Remount the bezels on both sides of the unit and secure them with the screws saved during
removal.

3

Remount the doors on both sides of the unit and secure them with the keylocks.

4

Inform the manager/owner that the unit can be returned to service.