beautypg.com

DNF Controls CP20 User Manual

Page 23

background image

Flex Control Network

®

, CP20 User Manual

Page 19 of 42

IP ADDRESS DISPLAY:

{ON}: Show IP address on LCD display

{OFF}: Do NOT show IP address on LCD display
(recommended)

REC KEY:

{REC}: Press only the REC key to start record.

{REC + PLAY}: Press and hold REC and then press
PLAY to start record.

PREROLL

Press the [Channel] key and then press {CHANGE}.
Use the numeric keypad to enter the new value. Press
[ENTER] to save the new value. Each Channel has its
own PREROLL value.

POSTROLL

For CAPTURE Function only. Set amount of postroll past
OUT point.

Press the [Channel] key and then press {CHANGE}.
Use the numeric keypad to enter the new value. Press
[ENTER] to save the new value. Each Channel has its
own POSTROLL value.

FAT-IN

For CAPTURE Function only. Set amount of record pad
before IN point.

Press the [Channel] key and then press {CHANGE}.
Use the numeric keypad to enter the new value. Press
[ENTER] to save the new value. Each Channel has its
own FAT-IN value.

FAT-OUT

For CAPTURE Function only. Set amount of record pad
after OUT point.

Press the [Channel] key and then press {CHANGE}.
Use the numeric keypad to enter the new value. Press
[ENTER] to save the new value. Each Channel has its
own FAT-OUT value.

GANG SYNC:

Used to GANG devices located on multiple DC20 Device
Controllers.

{No LTC + Ref Video}: GANG play and record will NOT
be frame accurate across devices connected to different
DC20s.

{With LTC + Ref Video}: GANG play and record will be
frame accurate across devices connected to different
DC20s.

NETWORK DELAY:

Only required when doing frame accurate GANG Play
across devices connected to different DC20s. Please
contact DNF Customer Support prior to changing.

GANG NETWORK
DELAY:

View the network delay of each ganged channel.