beautypg.com

Timeout, Retry, Switching – Comtech EF Data CDM-570/L Vipersat Parameter Editor User Manual

Page 55: Switching -39, Figure 2-26 automatic remote removal -39

background image

Chapter

2 -

Using Parameter Editor

2-39

Vipersat

Figure 2-26 Automatic Remote Removal

Timeout

The value entered in the Timeout field determines the number of cycles with no

connection (received ACKs) before a remote is removed from the network (the

burst map). This would be used, for example, where a mobile remote has

finished its assignment and has shut down.
After the number of cycles entered in the dialog above, the remote is removed

from the network and the bandwidth resources it had been using are available

for other uses.

Retry

The Retry field value determines the number of cycles which are allowed to

pass, following the removal of a remote, before that remote is returned to the

burst map and an attempt is made to re-establish a link.
This allows, again using a mobile remote as an example, shutting down the

remote at one location, moving it to a new location, and then automatically re-

establishing a connection to the satellite network.

Switching

For a detailed description of Automatic Switching in the VMS, refer to the

Vipersat Management System User Guide.
Clicking the Switching menu item displays the dialog shown in figure 2-27.

The fields available for edit on the sub-menu dialogs will vary, depending on

the function/role that this modem unit is performing in the network.
The Vipersat Automatic Switching feature allows the modem unit to automati-

cally adjust to varying bandwidth demands in the Vipersat network by switch-

ing between STDMA and SCPC. Automatic Switching must be enabled on a

This manual is related to the following products: