Vipersat

remote in the cycle begins transmitting. This delay prevents the remote from

overrunning the next terminal in the cycle.
The setting for this parameter should be obtained using the Vipersat STDMA

Calculator.

Remote List

Appears for Hub modems only.
Clicking the Remote List menu item below STDMA brings up the STDMA

Remote List dialog shown in figure 2-24.

Figure 2-24 STDMA Remote List, ECM

Use the buttons at the bottom of the dialog to perform the following actions:

• Add/Insert - Clicking the Add (Insert when a remote is selected) button

displays the Remote Entry dialog (figure 2-25). Use this dialog to enter

the Name of a remote, the remote’s IP Address, and to either disable or

enable the remote with the Disable check-box.
For STDMA set to GIR mode, enter the Switch Rate and the GIR value to

be used by this remote.