Comtech EF Data DMD2401/DMD2401L User Manual
Page 58

DMD2401/DMD2401L/DMD2401 IBS/IDR Satellite Modem
User Interfaces
TM065 - Rev. 3.3
4-19
+12Volt Mask:
{Pass/Fail, No/Yes}
Indicates the power supply voltage is out of range.
+5Volt Mask:
{Pass/Fail, No/Yes}
Indicates the power supply voltage is out of range.
Temp Mask:
{Pass/Fail, No/Yes}
Fail indicates that internal temperature of the modem is
out of range.
IntFPGA Mask:
{Pass/Fail, No/Yes}
Indicates a hardware failure on the Interface Card.
Battery Mask:
{Pass/Fail, No/Yes}
Indicates that the Internal Clock Battery is low.
RAM/ROM Mask:
{Pass/Fail, No/Yes}
Indicates an M&C Memory fault.
M&CProc Mask:
{Pass/Fail, No/Yes}
Indicates an M&C Microprocessor hardware failure.
Ref PLL Mask:
{Pass/Fail, No/Yes}
Indicates that the External Reference PLL is not locked.
Ext EXC Mask:
{Pass/Fail, No/Yes}
Indicates that the External Clock is not active.
Ext Ref Mask:
{Pass/Fail, No/Yes}
Indicates no activity on the External Reference.
D Card Mask:
{Pass/Fail, No/Yes}
Indicates a failure on the Daughter Card.
Backward Alr (menu):
RxBack Mask:
{Pass/Fail, No/Yes}
Indicates that the modem is receiving an Rx Alarm from
the modem that is receiving its data.
TxBack Mask:
{Pass/Fail, No/Yes}
Indicates that the modem is receiving an Tx Alarm from
the modem that is supplying its data.
Force Back:
{Normal, Alarm On, Alarm Off}
Indicates the state of the Backward Alarm.
Clear Alarms
{Ent = Y, Clr = N}
Clears all Latched Alarms.